Glow-Worm Boiler Fault Codes and Errors

Is your glow-worm boiler displaying some faulty codes that you are having a hard time cracking? Well, you need not worry anymore as you have come to the right place. In this guide, we will explain the meaning of the different fault codes that your boiler may be displaying and their possible causes.

Glow-Worm Boiler General Fault Codes and Errors

Fault

Code

Description Possible Cause
F00 Faulty flow temperatures sensor The NTC plug is loose or not plugged in, or is defective
F01 Faulty return temperature sensor The NTC plug is loose or not plugged in, or is defective
F10 The flow temperature sensor is short-circuited The NTC sensor is defective, or there is a  short circuit in the wiring
F11 There is a short-circuit in the return temperature sensor The NTC sensor is defective, or there is a  short circuit in the wiring
F12 & F91 There is a short circuit in the cylinder temperature sensor The NTC sensor is defective, or there is a  short circuit in the wiring
F13 A short circuit in the DHW cylinder temperature sensor The NTC sensor is defective, or there is a  short circuit in the wiring
F20 Excessive temperature detected in the boiler resulting in a safety switch-off Incorrect earth connection, faulty ignition electrode, or a defective flow/return NTC sensor
F22 Safety switch-off due to low water pressure in the boiler Insufficient water in the system or the water pressure sensor is defective
F23 The temperature difference between flow and return sensors in the boiler is too big, prompting a safety switch off The pump is blocked or is faulty, or the flow and return sensors are switched
F24 Temperature rise is too rapid Faulty pump, presence of air in the system, or system pressure is too low
F25 Excessive flue gas temperature Faulty optional flue gas safety temperature limiter
F27 Flame detection error Faulty flame detection electrode or the boiler electronics are moist
F28 Ignition failure Faulty detection electrode or there is no gas supply, or gas flow pressure is too low
F29 Flame loss Gas supply temporarily stopped, or the ignition transformer registered a spark failure
F32 The fan protection feature is active due to fan speed being outside tolerable values The fan is blocked, faulty PCB unit, or fan not correctly plugged in
F33 The fan frost protection feature is active due to an air pressure switch fault Faulty pressure monitor or fan speed set too high, resulting in inadequate air supply
FA9 Low voltage resulting in an eBUS  fault The eBUS is short-circuited or overloaded
F61 Faulty gas control system The gas valve is defective, or there is a short-circuit in the valve connection
F64 Faulty electronics or sensors or analogue-to-digital converter The boiler has defective electronics, or the flow/return sensor is short-circuited
F67 Incorrect flame signal Faulty electronics or implausible flame signal
F70 The DSN product code is invalid The PCB and display units were replaced at the same time, and the DSN number was not reset
F71 The flow/return sensor is displaying a constant value The flow/return sensor is defective or incorrectly placed
F72 Notable deviation detected in water pressure/ return temperature sensor The temperature difference in the flow/return NTC is too big. The return sensor could also be defective
F73 Faulty water pressure sensor The water pressure sensor is defective, or not connected, or is short-circuited
F74 Faulty water pressure sensor due to an electrical  fault The connection to the water pressure sensor has a short-circuit, or the sensor has an internal fault
F75 Faulty pressure sensor The pressure switch may be defective
F77 Presence of condensate or smoke fault in the boiler The condensate pipe is blocked, or the flue non-return flap is defective
F78 Defective safety cut-out in the primary heat exchanger There is a mismatch between the safety cut-out feedback and the gas valve feedback
F78 The DHW outlet sensor has been interrupted at the external controller The hot water NTC is not connected
F83 EEPROM error Defective boiler electronics
F83 Faulty burner temperature sensor The burner temperature sensor is defective, or there is insufficient water in the boiler system
F84 Faulty flow/return temperature sensor The flow and return sensors have been inverted or incorrectly installed
F85 Faulty temperature sensor The temperature sensor is incorrectly installed, or the flow and return sensors have been installed on the same pipe
F85 The boiler electronics are overheating The boiler electronics are defective
F.87 Faulty electrodes The electrodes are faulty or incorrectly connected
F88 Faulty gas valve The gas valve is defective, not connected, or is connected incorrectly
F88 Faulty underfloor heating contact The underfloor heating contact is open, disconnected, or defective
F88 The flame is unstable Presence of air in the gas, low gas pressure, faulty electrodes, or incorrect air ratio
F89 Pump fault The pump is not connected, is incorrectly connected, or there is a short-circuit in the cable harness

 

  • Buy Now Pay Later Schemes!
    • Interest Free Credit
    • Buy Now Pay Later
    • Spread Payments
    Finance Options
  • Free Boiler Quotes

    No-obligation to buy!

    • From the comfort of your home
    • You choose the best company
    • Gas Safe trusted companies
    Get Quote NOW
Need a New Boiler

Get FREE quotes from tradesmen in your area today. What are you looking for?

Get Quote NOW REQUEST A CALLBACK